BTSYD - ORION APPLICATION SOLUTION TISAB #940909
- MSDS: BTSYD
- Manufacturer: ORION RESEARCH INC
- Product Name: ORION APPLICATION SOLUTION TISAB #940909
- National Stock Number: 6630-01-032-1427
Product Identification
Product ID:ORION APPLICATION SOLUTION TISAB #940909
MSDS Date:05/31/1989
FSC:6630
NIIN:01-032-1427
MSDS Number: BTSYD
Responsible Party
BOSTON, MA 02129
US
Info Phone: 617-242-3900
Cage: 30260
Contractor
Telephone: 617-242-3900
Cage: 30260
Ingredients
ACETIC ACID (SARA III)
CAS: 64-19-7
RTECS: AF1225000
Fraction By Weight: 1.4%
OSHA PEL 10 PPM
ACGIH TLV: 10 PPM/15 STEL; 9394
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
SODIUM ACETATE
CAS: 126-96-5
RTECS: AJ4375000
Fraction By Weight: 8.2%
SODIUM CHLORIDE
CAS: 7647-14-5
RTECS: VZ4725000
Fraction By Weight: 5.8%
TRANS 1,2 DIAMINO CYCLOHEXANE TETRAACETIC ACID
CAS: 25637-70-1
Fraction By Weight: 0.1%
DEIONIZED WATER
Fraction By Weight: 84.2%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION MAY CAUSE NAUSEA,
BREATHING DIFFICULTIES, AND DAMAGE TO STOMACH AND DIGESTIVE TRACT.
LOW HAZARD FOR SKIN AND INHALATION.
Effects of Overexposure:IRRITATION OF RESPIRATORY TRACT, UPSET STOMACH
OR NAUSEA, IRRITATION OF EYES, NOSE, THROAT.
Medical Cond Aggravated by Exposure:RESPIRATORY AILMENTS, PERSONS WITH
SENSITIVE SKIN MAY BE AFFECTED.
First Aid
First Aid:EYES AND SKIN: IRRIGATE WITH PLENTY OF WATER. INTERNAL:
DILUTE WITH LARGE AMOUNTS OF WATER. DO NOT INDUCE VOMITING. CONSULT
PHYSICIAN.
Fire Fighting
Flash Point:NONE
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL FOAM OR MIST
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:VACUUM UP AND SET ASIDE FOR WASTE DISPOSAL
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM OXIDIZERS AND
CAUSTICS.KEEP SEALED/ STORE AT ROOM TEMP. ACETIC ACID IS A CERCLA
HAZARD AND SUBJECT TO SECTION 304 OF SARA TITLE III
Other Precautions:WASH HANDS THOROUGHLY WITH SOAP AND WATER AFTER
WORKING WITH THIS MATERIAL.RATINGS SCALE (0-4) HEALTH 1, FIRE 1,
REACTIVITY 0, SPECIFIC NONE.
Exposure Controls
Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:LOCAL EXHAUST RECOMMENDED
Protective Gloves:RECOMMEND USE
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER EACH USE OF THIS PRODUCT
Supplemental Safety and Health
NONE
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.07
pH:5-5.5
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID, VINEGAR LIKE ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, (CHROMIC ACID, SODIUM PEROXIDE), CONTACT WITH STRONG
CAUSTICS CAN CAUSE SPATTERING.
Stability Condition to Avoid:HEAT OR FLAME
Hazardous Decomposition Products:TOXIC GASES SUCH AS CARBON MONOXIDE
MAY BE RELEASED DURING A FIRE.
Disposal
Waste Disposal Methods:DILUTE NEUTRALIZED SOLUTION DOWN DRAIN WITH
EXCESS WATER; OBSERVE ALL FEDERAL, STATE AND LOCAL LAWS WHEN
DISPOSING OF THIS SOLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.